File:Ss-1.svg: Difference between revisions
From Elliptic Curve Crypto
Errata |
|||
| Line 3: | Line 3: | ||
This version seems to have an inverted output from the controller chip that needs to be fixed. | This version seems to have an inverted output from the controller chip that needs to be fixed. | ||
Transistor Q1 should probably be PNP instead of NPN. | |||
Revision as of 05:23, 27 March 2026
Summary
Solar Cell System with Charge Controller and Battery
This version seems to have an inverted output from the controller chip that needs to be fixed.
Transistor Q1 should probably be PNP instead of NPN.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 22:55, 28 March 2026 | 1,260 × 765 (365 KB) | Rational Point (talk | contribs) | fixed upside down diode | |
| 21:52, 27 March 2026 | 1,260 × 765 (358 KB) | Rational Point (talk | contribs) | specified component values; added lamp and switch | ||
| 06:09, 27 March 2026 | 1,260 × 765 (340 KB) | Rational Point (talk | contribs) | fixed inverted output, layout | ||
| 16:08, 25 March 2026 | 1,260 × 765 (332 KB) | Rational Point (talk | contribs) | Solar Cell System with Charge Controller and Battery |
You cannot overwrite this file.
File usage
The following page uses this file: